Design optimisation of silicon-based MEMS sensors dedicated to bioaerosols monitoring - ESIEE Paris Accéder directement au contenu
Communication Dans Un Congrès Année : 2015

Design optimisation of silicon-based MEMS sensors dedicated to bioaerosols monitoring

Résumé

Due to recent paradigm changes for the monitoring of air pollution, assessing human exposure to (bio)- aerosols with low-cost sensors is expected to be of growing importance. In this context, our work subsequently investigates the development of Si-based gravimetric instruments. Thus particle-resonator interactions are considered to provide a particle detachment criteria as well as geometrical features ensuring performances both in terms of sensitivity and uniform resonator response. Analytical and numerical methods have been carried out and confronted to experimental results.
Fichier principal
Vignette du fichier
Design optimisation of Silicon-based MEMS sensors.pdf (837.25 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-01771681 , version 1 (24-05-2023)

Identifiants

Citer

Brice Berthelot, Emmanuelle Algre, Stéphane Moularat, Enric Robine, Evelyne Gehin. Design optimisation of silicon-based MEMS sensors dedicated to bioaerosols monitoring. 2015 Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS (DTIP), Apr 2015, Montpellier, France. ⟨10.1109/DTIP.2015.7161009⟩. ⟨hal-01771681⟩
85 Consultations
9 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More